Please check out our troubleshooting tips if PDF files do not open. To process an application, we need all the documents listed in our checklist. The processing time begins only when we have received the documents. For some documents, certified photocopies are mandatory to confirm that the photocopy corresponds to the original. It bears the official stamp and signature of the certifying authority.

The checklist indicates for each document if a regular or a certified photocopy is required. The ZAB needs an overview of your entire educational path to evaluate your university degree, including the kind of secondary school you attended and graduated from.

There is a considerable variety in educational systems of different countries. Therefore, we may need different documents to evaluate degrees. In the checklists, we included the most important terms in the language of the respective country to make the application process easier for you.

What if the pumps power supply fails? What if a compressor is started with the suction valve closed? What if a compressor is started with the discharge valve closed? What if a compressor overheats? What if a compressor is subjected to freezing conditions? What if a compressor underspeeds? What if a compressor overspeeds?

What if a compressors power fails? What if a compressors coupling to driver fails? What if a compressors suction liquid knockout drum overflows? What if air enters the compressor? What if a compressors feed line fails or has too low a pressure? What if a compressors feed pressure increases?

What if a compressors relief valve fails closed? What if a compressors relief valve opens inadvertently? What if a compressors seals, valves, or piston rings leak?

What if a compressors tail rod breaks? What if a compressor is subjected to excessive vibration? What if a compressor instrumentation fails? What if a compressor is not cleaned or maintained? What if a compressor handles substances containing contaminants or particulate matter? What if toxic or corrosive gases are introduced to the compressor inlet stream? What if a compressor is submerged underwater? What if a compressor is exposed to a fire?

What if an exchanger tube or shell flow rate is decreased? What if an exchanger tube or shell flow is stopped? What if the tube or shell feed temperature increases? What if the tube or shell feed temperature decreases? What if the tube or shell feed composition changes e. Exchanger What if an exchanger pressure increases? What if an exchanger pressure decreases? What if an exchanger tube ruptures? What if an exchanger experiences excessive fouling?

What if an exchanger loses insulation? What if an exchanger internals plug? What if an exchanger internals collapse? What if an exchanger relief valve lifts or leaks by? What if an exchanger shell ruptures due to internal corrosion, defective materials, or poor workmanship? Exchanger piping What if an exchanger tube or shell outlet block valve is closed?

What if an exchanger drain or vent valve is open or leaking? Exchanger external factors What if an exchanger or piping is damaged by a motor vehicle collision?

What if an instrument or electrical component has an electrical fault? What if an exchanger is struck by lightning? What if a reactor leaks? What if a reactor ruptures? What if a reactor experiences corrosion internally or externally? What if a reactor experiences erosion? What if a reactor loses agitation or agitates too little? What if a reactor agitates too much? What if a reactor loses cooling? What if a reactor cools too much? What if a reactor loses heating?

What if a reactors heating rate is increased or decreased? What if a reactor is charged too fast? What if a reactor is charged too slowly? What if a reactor is overfilled? What if a reactor is underfilled? What if a reactor is charged with an improper reactant ratio? What if a reactor loses a reactant feed? What if a reactor is charged with a wrong material? What if a reactor is charged in the wrong sequence of reactants? What if a reactor is charged with no or too little catalyst?

What if a reactor vent line plugs? What if a reactors pressure is too high? What if a reactors pressure is too low? What if a reactors relief valve opens inadvertently?

What if a reactors relief valve fails closed? What if a reactors controls fail? What if a reactors instrumentation fails? What if a reactors discharge line plugs? What if a reactors discharge valve opens too soon? What if a reactor loses inerting? What if a reactors lining fails? What if a reactors coolant leaks into reactants? What if a reactor contents spontaneously ignite? What if a reactor produces hazardous byproducts? What if a reactors side reactions predominate?

What if a reactor becomes contaminated? What if a reactor is not cleaned or maintained? What if a column leaks? What if a column ruptures? What if a column experiences corrosion internally or externally? What if a column loses reflux or cooling? What if a column loses heating? What if a column loses feed? What if a columns feed is increased?

What if a columns feed is too hot? What if a columns feed is too cold? What if a columns feed composition changes? What if a column loses liquid level? What if a columns discharge valve opens too wide? What if a columns discharge valve is blocked? What if a columns pressure is too high? What if a columns pressure is too low? What if a column is blocked in but heat remains on?

What if a column under vacuum leaks air in? What if a column is subjected to fire conditions? What if a columns relief valve fails to open? What if a columns relief valve opens inadvertently? What if a columns instrumentation fails? What if a column experiences internal blockages to inlet diffusers or trays? What if a column experiences gas or liquid entrainment? What if the flare flow rate is greater than design flow rate? What if the flare experiences a flameout? What if the flare is fed an inadequate amount of combustion air?

What if the flare is fed excessive combustion air? What if the flare is fouled with solids? What if liquids carry over from upstream knockout vessel to flare? What if the flare creates excessive radiant heat levels? What if the flare cannot be lighted? What if the flare blower or motor fails? What if the instrument air supply is lost? What if the fuel gas supply is lost?

What if the flare control panel malfunctions? What if the fuel supply pressure decreases? What if the fuel supply pressure increases? What if solids or coke build up on stack or nozzles? Flare piping What if the flare inlet block valve is closed? What if the fuel gas supply block valve is closed?

What if the fuel gas regulator fails open or closed? What if the fuel shut-off valve fails to open or close as required?

What if solids form possible hydrates in relief outlet line? External factors What if stack or piping is damaged by a motor vehicle collision? What if the relief stack is struck by lightning? What if excessive vegetation is allowed to grow at base of flare?

What if the generator alarms or shutdowns fail? What if the generator space heaters fail to operate? What if the generator becomes overloaded? What if the fuel supply becomes contaminated? What if the engine cooling equipment becomes fouled? What if the voltage regulator fails high or low?

What if an exciter fails open? Motors What if a motor overheats? What if a motor fault occurs? What if a motor bearing fails? What if a motor turns in the reverse direction?

What if the motor grounding cable is not connected? Motor control center What if a main breaker trips? What if voltage is high or low?

What if an internal fault occurs? What if a starter fails open or closed? What if a motor overload fails to operate? What if a motor circuit protector opens? What if a control transformer fuses open? What if the motor control center is not grounded? Switchgear What if an incoming voltage is too high or low? What if an incoming voltage frequency is too high or low? What if a main breaker trips? What if a breaker control voltage fails?

What if the breaker interlocks are bypassed? What if a grounding resistor is disconnected? What if a cooling tower has excessive fouling of internals? What if a cooling tower has power loss to pumps or fans? What if a cooling tower has containments in water? What if a cooling tower has excessive fan vibration?

What if a cooling tower has flammable mixtures in the water? What if the cooling tower motor overheats? What if a cooling tower catches on fire? What if the cooling tower structure is deteriorated? What if the cooling tower motor is not grounded? What if the facility air system fails? What if the instrument or utility air system fails? What if the breathing air system fails? What if the cooling water system fails?

What if the cooling ammonia system fails? What if the cooling Freon system fails? What if the cooling steam system fails? What if the cooling nitrogen system fails? What if the electrical system fails? What if the fuel gas system fails? What if the natural gas system fails? What if the propane fuel system fails? What if the bunker C fuel system fails? What if the heating oil fuel system fails? What if the kerosene fuel system fails? What if the helicopter refueling system fails?

What if the diesel fuel system fails? What if the steam heating system fails? What if the electric heating system fails? What if the transfer oil heating system fails? What if the inert gas blanketing system fails? What if the flush oil system fails?

What if the seal oil system fails? What if the mineral oil system fails? What if the heat transfer oil system fails? What if the purge gas system fails?

What if the NDT radioactivity system fails? What if the sanitary sewer system fails? What if the storm sewer system fails? What if the oil water drains system fails open or closed system? What if the steam system fails? What if the facility water system fails? What if the city water system fails? What if the well water system fails What if the fire water system fails?

What if the water storage system is empty? What if the chilled water system fails? What if the zeolite water system fails? What if the demineralized water system fails? What if the communications network fails?

What if the plant alarm system fails? What if the security system fails? What if the backup utility system fails? What if unqualified personnel prepared the engineering design?

What if an error in engineering calculations was performed? What if incorrect materials are ordered or used? What if construction is performed improperly? What if quality assurance procedures are not available or followed? What if improper or inadequate start-up procedures are written? What if improper or inadequate start-up procedures are used? What if improper or inadequate operating procedures are written?

What if improper or inadequate operating procedures are used? What if instructions for modifications are not provided? What if improper maintenance is performed? What if improper inspection is performed? What if improper decommissioning procedures are used?

What if improper demolition procedures are used? What if management is inadequate or unsatisfactory? What if regulations have not been complied with?

Operators What if an operator does not perform an action? What if an operator performs the wrong action s? What if an operator performs an action at the wrong place? What if an operator performs an action in the wrong sequence? What if an operator performs an action at the wrong time? What if an operator makes an incorrect reading?

What if operators work long hours? What if operators are not provided with supervision? What if operators are not trained? What if operators do not understand or know the hazards of the process? What if an operator is inundated with instrumentation readings or alarms? Equipment What if access to equipment is not possible? What if a valve is too frozen to operate? What if a valve is not marked for identification? What if an electrical switch does not indicate its function?

What if an emergency egress route is not marked? What if an emergency egress route is blocked? What if equipment operation is opposite to normal convention? What if color coding is not used e.

What if adequate lighting is not available? What if instructions are not provided in indigenous languages? What if indicator lights are not working? What if indictor light lenses are of the wrong color?

What if air breathing masks do not fit personnel? What if oil spill boom is too heavy to move? What if an emergency alarm does not operate? What if an emergency alarm cannot be heard? What if an emergency alarm is confused with other instructional tones?

What if no communication devices are available? What if maintenance is not performed accurately? What if maintenance is performed at the wrong time? What if maintenance is performed with the wrong materials or parts? What if maintenance does not restore the component to working conditions? What if maintenance inadvertently initiates a future hazardous condition?

Sampling What if sampling is performed irregularly? What if sampling is performed improperly or with improper containers? What if sampling is performed from the wrong system? What if sampling contaminates samples? What if sampling is not properly coordinated with others or with prudent controls? Testing What if testing is performed improperly? What if testing is not performed thoroughly or realistically?